After the successful introduction of the 4th generation of our WiO sensors last year, the update and further development at system level now follows: The multiple WiO setup with central monitoring unit. For parallel monitoring of up to six WiO sensor systems.
This setup allows flexible monitoring of several plants with regard to moisture in oil and the respective current media temperature. The evaluation of the analog values takes place separately for each plant and is triggered in each case by an individually adjustable pre-alarm and main alarm. On the basis of time trend curves, which can be viewed and analyzed for each channel via touch on the display, the user is able to take immediate measures on the plants or to plan them in advance.
An example? Monitoring of the drives of a seagoing vessel: one main unit with five auxiliary units. The individual sensors FRG00035, connected to the MPU010 boxes, are connected to the central display unit. - For detailed information, please contact us directly.